David Pastrnak Baby Died How, Sierra 60 Gr Tmk, For Sale By Owner Canajoharie, Ny, Moors Murders Location, Articles S

Sorry we couldn't be helpful. Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . Open navigation. or, which is default value. Please provide the following information as well: Ginlong Technologies Co., Ltd.No. We have just had a solar system installed. No-Grid - El inversor no reconoce la red. A Solis 5K inverter is used here as an example.Please follow the instructions below:Install the datalogger: NOTEOnly rotate the black circle, not the sliver cover. If it does not reconnect than with your laptop/phone search for new open access point and try to connect to wifi stick, maybe it has lost settings. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. logger's local network which allows you to link it to the home network. Data Logger into the port and be sure to secure it by tightening the black connector. Press the button for 5 seconds to reset, 2 red lights are on and off at the same time, https://www.youtube.com/watch?v=nUjcDcY8-Ws, Solis DLS-G GPRS Datalogger setup and troubleshooting, Solis RHI HMI Update German Documentation. Let us know how can we improve this article! Stepl: Enter the main page of the Soliscloud APP, and click the Add plant at the bottom. Step2: Connect the datalogger to the corresponding 4-pin COM port of the inverter. SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering system owners with all the data they need. We use cookies to try and give you a better experience in Freshdesk. In general you want to ensure the router is not blocking the IP address from the WIFI stick. Is there a trick to setting it up properly that I am missing? solis app gone off-line MATTYON Apr 14, 2022 hi all my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device" i wont get to it until tonight has anyone seen this before is it just the wifi (or has the whole system gone down) and will re-booting the system put it right Select Network, fill in the IP address assigned by the router/network administrator, Let us know how can we improve this article! Users can easily check device lnformatlon by logging In the monitoring center. The [RESET] button on the back is used for the connection. SolisCloud is the new generation of intelligent PV system monitoring. The device must be installed away from the strong magnetic field produced by large electrical appliances such as microwave ovens, refrigerators, telephone, metal walls, etc. A Solis 5K inverter is used here as an example. *, We appreciate your effort and will try to fix the article. Log in to the page , the username is "admin" and the password is also "admin" 5. solis S3-WIFI WiFi Stick Datalogger Installation Guide Your email address will not be published. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. This should serve as a reminder to manually save your drafts if you wish to keep them. 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stick, Solis DLS-G GPRS Datalogger setup and troubleshooting, Adding a new inverter to an existing EPM set-up, EPM 5G Plus- Abnormal Offline on Soliscloud. Dataloggers can be scanned or added manually by entering in the serial number. Internal DC Short: In the inverter head, or the wirebox? I will ask AGL for a replacement. on Properties, select internet protocol IPv4(TCP/IPv4). Yes my data logger also glows red as well, does appear to be a LED keepalive in the unit to show its still transmitting data to the mothership. Open theSolisCloudapp on your phone. Solis WIFI Stick Troubleshooting TOP 5 Issues: 1. We pay our respects to their Elders past, present and emerging. These limits are designed to provide reasonable protection against harmful interference in a residential installation. After you connect verify the WIFI stick sees the inverter. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Note: the SolisWiFilogger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. It is highly recommended to first connect your phone to the home network that you wish to connect theWiFilogger to. Select Network, fill in the IP address assigned by the router/network administrator, 1: Connect LAN stick to operational inverter to provide power to LAN stick. It used to come back eventually but sometimes I went up to the attic and just unplugged it from the inverter for a second and then put it back in. Internal DC Short: In the inverter head, or the wirebox? Please follow the instructions below: Step3: Use your mobile phone to send a text message to the SIM card in the stick. Verify the RSSI (signal strength) is higher than 15%. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. GitHub - simon3270/ginlong-python: Get logging data from Solis Inverter We use cookies to try and give you a better experience in Freshdesk. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed; Reset WiFi Stick to Factory Settings my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device", is it just the wifi (or has the whole system gone down) and will re-booting the system put it right. 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! When I am logged into the data logger via wifi the status says that it is connected and when I test the connection on the server page it seems to be all good. Internal DC Short: In the inverter head, or the wirebox? All is fine for about a week and then I noticed that the system would go offline a couple of times throughout the day (morning and night) with varying durations. Firmware Version: 3.16.9. i have recently installed a solar inverter which has a data logger > having an issue connecting it to my wifi network but it works fine with . When the network environment of the plant has a firewall, you need to add the server information to the white list of the firewall. 1. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. i cannot connect my solar wifi data logger to my wifi but it gets solis SOL-DLS-W Data Logger Wifi Stick User Guide - Manuals+ Connect the antennae to the data logger; Plug the logger into the inverter - be sure the inverter is on with at least DC power; Open the Wi-Fi settings on your phone and then search for new networks . It's probably just the datalogger that's lost connection. SolisCloud - Apps on Google Play If it has a good connection to the inverter do the following steps: 1. We and our partners use cookies to Store and/or access information on a device. Did you find it helpful? If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-Reorient or relocate the receiving antenna.-Increase the separation between the equipment and receiver.-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-Consult the dealer or an experienced radio/TV technician for help. Then plug the Wifi Data Logger into the port and be sure to secure it by tightening the black connector. My data logger appears to be working fine but I also notice it now glows red, appears to be a red LED inside the logger. Select Network, fill in the IP address assigned by the router/network administrator LAN Stick - DLS-L 1: Connect LAN stick to operational inverter to provide power to LAN stick. Then plug theWifiData Logger into the port and be sure to secure it by tightening the black connector. Solis Data Logging Stick GPRS/WiFi Installation Video Solis 46.7K subscribers 15K views 9 months ago Solis monitoring system is centred around the photovoltaic power station, focusing on. Solarman Data Loggers (4-pin only) DLS-W: WiFi only data logger; DLS-L: LAN only data logger; DLS-C: 4G cellular only data logger; Solis is no longer selling these products in the US; Our distributors likely still have stock of these products but we are not promoting them; Solarman loggers do not support remote settings changes or firmware updates Copyright@2020 Ginlong Technologies All rights reserved. No, Modified on: Fri, Jun 10, 2022 at 11:55 AM. Issue was more to do with the router's wifi signal not being strong enough in the attic than the data logger itself. Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the . Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. solis S4-GPRS GPRS Stick Datalogger Installation Guide, solis SOL-DLS-W Data Logger Wifi Stick User Guide, DAIKIN BRP069B45 WiFi Adapter Installation Guide, ideal lux 306445 Clara PL Square 4000K Ceiling Light Owners Manual, Microderm GLO NVD-MGM-GR1802 Blackhead Remover Pore Vacuum User Guide, AVALON A3F Bottom Loading Water Cooler Water Dispenser User Manual, boAt Wave Lynk Voice Premium Smartwatch User Manual, motorline RAP50 Microwave Presence Sensor User Manual, kbice FDFM1JA01 Self Dispensing Nugget Ice Machine User Guide, LUMINAR EVERYDAY 59250 2ft LED Linkable Plant Grow Light Owners Manual, Viatom Blood Pressure Monitor BP2 & BP2A User Manual. Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide : Solis Connect the data logger to the corresponding 4-pin COM port of the inverter. According to the website my data logger is offline. app on your phone. Intro Inverter Logger Device Connect Summary Device Make Sure Phone Connected to WiFi Network Please Make Sure Phone Connected to WiFi then Click Next 15:38 Back Connect WiFi SN: 4005854756 Enter Netwo. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Solis-1P(3.6-10)K-4G inverters DSP firmware updating process Otherwise, the communication quality may be affected. No-Grid - El inversor no reconoce la red. I have tried different settings with the data logger setup without having any luck. 2.4 GHz. This video will. Hi Everyone, I got some help with the Ginlong Wifi and I have been able to set the system up and log onto the Ginlong monitoring websitebut the system says it is 'loading' but no data is shown on the site. You can select the corresponding server information according to the model of data logger used by the plant. Wi-Fi trensmitting power: 802.11b/g/n: +20dBm/+18dBm/15dBm (Max) Data collection intervals: 5 minutes (adjustable:1-20 minutes) Preferences setting: Web server/Serial AT instruction. *, We appreciate your effort and will try to fix the article. Ginlong Solis solar inverters Preamble. No-Grid - El inversor no reconoce la red. Technician check pins 1 and 2 for 5VDC, 3. This process can also be used to move a Solis Data Logger from one site to another. This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. Shows the connection status between the datalogger and the inverter. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. 2: On the computer, click on the Network Connections and select the Local Connection. Solis Inverter Data Logger Issue : r/solar - reddit.com You can learn more about what kind of cookies we use, why, and how from our Privacy policy. Open the SolisCloud app on your phone. 2023 AGL recognises the Aboriginal and Torres Strait Islander peoples as the Traditional Owners of the lands on which we work, and we acknowledge those communities' continuing connections to their lands, waters and View the total data of your PV plant. Solis Data Loggers Explained : Solis :). Ginlong Solis(Stock Code: 300763.SZ) is one of the oldest and largest global string inverter specialists, that manufactures string inverters for converting DC to AC power and interacting with utility grid, which help reduce the carbon footprint of human s Reliability Safety Capacity WiFi Data Logger. Then plug the. Step 3: Confirm the plant information.Click Create a plant.Step 4: Click View plant to enter the plant homepage, then add the datalogger. 0:00 / 1:28 Reset instruction for Solis Datalogger Solis 46.7K subscribers Subscribe 130 37K views 3 years ago When the datalogger fails, you can try to reset it to repair. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //.